Skip to main content

Multiple Copies Classic & RTC with Report Page No. Reset with Each Copy - Part 1

Hi all,

I found lot of Queries about this, so lets try to do this. I Divide this article into three parts -

1) Enabling Multiple Copies in a standard Report - Classic. [This Article]
2) Enabling Multiple Copies in a standard Report - RTC.
2) Set Page X / Y in Multiple Copies printing Reports.

For the Demo I will be using Standard Report 16593 - Excise Invoice. This report have none
of the above listed points.

In this post we will try to use multiple copies options in this report, taking reference  Report 206 - Sales - Invoice.

1. Create a new Data Item With Name - CopyLoop after Sales Invoice Header.

2. Indent Other Data Items Below It to one more level as shown below.

BEFORE

AFTER

3. Set Properties for Copy Loop Data Item as - New Payer per record to YES.


4. Change the Property of Integer Header as shown below.


5. Cut Code from Sales Invoice Header - Trigger OnAfterGetRecords.


6. Paste the code IntgerHeader - OnAfterGetRecords.


7. Also cut the line of InitVariables from Sales Invoice Header onAfterGetRecords and Paste it in IntegerHeader - OnAfterGetRecords.

8. Taking Reference from Report 206 - Copy and Paste Code in Copy Loop - onPreDataItem and Copy Loop - OnAfterGetRecords as shown below.


9.Create Variables as per compilation Errors as shown below.




10.Add option of No. of Copies in Request Form.


11. Add the Copy Text & OutputNo From Report 206 in Section as shown below.


12. Now lets Run the Report in classic. yeah it works as expected. But it doesn't work in RTC that way.

Let's see changes that need to be done in RTC in Next post.

Regards,
Saurav Dhyani

Comments

Post a Comment

Popular posts from this blog

VIEW SERVER STATE permission on SQL Server?

Hi all, Sometime While trying to Login into a database we face an error message as shown below. --------------------------- Microsoft Dynamics NAV Classic --------------------------- You cannot start Microsoft Dynamics NAV Classic because you do not have the VIEW SERVER STATE permission on SQL Server. Contact your system administrator. --------------------------- OK    ---------------------------

RTC Report It is not possible to instantiate the Visual Studio bridge.

Hi all, As a Navision developers I have Multiple Versions of Navision running in single Machine. As discussed Earlier in the post how to run multiple Version of RTC in single machine. So my machine have following details for RTC Versions - NAV 2009 R2    - is installed. NAV 2009 SP1  - is copied at C:\Program Files (x86)\Microsoft Dynamics NAV\60\NAV 6.0 SP1 IN\ NAV 2009         - is copied at C:\Program Files (x86)\Microsoft Dynamics NAV\60\NAV 6.0 IN\ This approach has been working great for execution of Classic and RTC Clients. However, after installing Dynamics NAV 2009 R2, if i tried to view the Layout for an NAV 2009 SP1 Report i was getting the following error: ---------------------------  Microsoft Dynamics NAV Classic  ---------------------------  It is not possible to instantiate  the Visual Studio bridge.  ---------------------------  OK    --------------------------- After searchi...

Dynamics NAV - All that you need to know about MenuSuites.

Hi Readers, This article is based on a request from a blog reader who wanted to understand about MenuSuite in Dynamics NAV. If you have started working with Business central with AL Code then it does not apply to those releases but if you are interested go ahead. Let's start with Future - In Latest and greatest version of product MenuSuite are obsolete and no longer used. So this article applies if you want to learn about C/AL MenuSuite.